Transformer Oil Insulation
Kit - 14000 Series
|
Model No. |
Output Voltage
(AC Volts)** |
Capacity |
Input |
Duty |
|
Manual Operated |
Motor Operated |
|
SOT 50 MN |
SOT 50 MOT |
0 - 50 KV |
500 VA |
230 V +/- 10%
50HZ
1 Phase AC |
Intermittent
(i.e. : 1 Minute
withstand test
or momentary
breakdown
test) |
|
SOT 60 MN |
SOT 60 MOT |
0 - 60 KV |
600 VA |
|
SOT 70 MN |
SOT 70 MOT |
0 - 70 KV |
700 VA |
|
SOT 90 MN |
SOT 90 MOT |
0 - 90 KV |
900 VA |
|
SOT 100 MN |
SOT 100 MOT |
0 - 100 KV |
1000 VA |
|
SOT 120 MN |
SOT 120 MOT |
0 - 120 KV |
1200 VA |
**
Continuously variable with
centre point of H.V. winding
grounded.
Special Features
-
Mains ON/OFF switch
-
Neon Lamps to indicate L.T.
ON & H.T. On
-
Autotransformer for smooth &
continuous variation of
output voltage
-
Zero start inter locking
-
HT Chamber door interlocking
-
Overvoltage indication lamp
to indicate regular not at
zero for motorised set
-
Memory device with push
bottom switch to show the
break down voltage
-
96 Sq. MM. AC moving iron
type voltmeter connected to
the L.T. Side and scaled in
KV
-
Provided with test Vessel
(Oil Cell) made from
non-absorbent insulating
material fitted with two
brass spheres of diameter
between 12.5 to 13 mm places
at a distance of 4mm or
2.5mm. Agauge is provided
along with the cell to
adjust the gap.
Servoline make oil
test set is ideal for
speedy & accurate testing of
breakdown/withstand test of
transformer and circuit
breaker oil, in accordance
with IS 6792 : 1992 for oil
testing.
Technical Features
Input
230 V +/- 10%, 50 Hz, 1
Phase, Ac
|
Model No. |
Output
Voltage
(AC Volts)* |
Capacity |
Input |
Duty |
|
Manual
Operated |
Motor
Operated |
|
SOT 50 MN |
SOT 50 MOT |
0 - 50 KV |
500 VA |
230 V +/- 10%
50HZ
1 Phase AC |
Intermittent
(i.e. : 1 Minute
withstand test
or momentary
breakdown
test) |
|
SOT 60 MN |
SOT 60 MOT |
0 - 60 KV |
600 VA |
|
SOT 70 MN |
SOT 70 MOT |
0 - 70 KV |
700 VA |
|
SOT 90 MN |
SOT 90 MOT |
0 - 90 KV |
900 VA |
|
SOT 100 MN |
SOT 100 MOT |
0 - 100 KV |
1000 VA |
|
SOT 120 MN |
SOT 120 MOT |
0 - 120 KV |
1200 VA |
* with
centre point of H.V. winding
grounded.
General Arrangement
The set will be consisting
of the following : H.T.
Transformer, Control
Circuit, test Cell with
electrode, guage and supply
input cable of at least 2
meters length with 3 pin
plug. The set is in single
unit. Instruction mannual
with circuit will be
supplied along with the set.
H.V. Transformer
H.V. transformer use din the
test set is double wound
Resin-Cast High Voltage
Transformer. The H.V.
winding of the high voltage
testing transformer is of
graded insulation with
center point of H.V. winding
grounded. This testing
transformer is specially
designed to withstand
frequent spark over or
momentary short circuit
conditions under which such
testing transformer are
supposed to operate.
Protection : Beside
main switch and fuse in the
input side. one "ON" and one
"OFF" push button switch
along with C.T. and
conductor provides a snap
acting automatic tripping of
H.V. circuit in case of
overloaded or breakdown of
oil sample under test.
Over Voltage Indication :
Over voltage indication lamp
and alarm is provided for
motor operated Sets.
Over Voltage Protection :
For motorised sets, over
voltage protection is
provided.
Metering : 96 SQ. MM.
Ac moving iron type
voltmeter connected to the
L.T. side and scaled in KV.
Mode of Operation :
Sets will be available
either in manual or in motor
operated mode. In motor
moderated sets, the
regulators are adjusted at
approximately 2KV/sec. rate
of rise of voltage.
Test Cell : The test
vessel (Oil Cell) fitted
with two brass spheres of
diameter between 12.5 to 13
mm, placed at a distance of
4 mm or 2.5 mm. The test
vessel made from
non-absorbent insulating
material. Gap of the spheres
can be adjusted by adjusting
one sphere while the other
being fixed. Dimensions are
generally as per IS 6792 :
1992. A gauge is provided
along with the cell to
adjust the gap.
Test Set Housing :
The set is in single
unit. All the components are
housed within a nicely
painted M.S. cabinet
provided with wheels, M.S.
buffer and handles fore easy
movement. A transparent
cutout with suitable
interlocking devices
provided for covering the
H.T. side. The set will not
get energised unless this
H.T. end is covered. The oil
cell is to be placed between
the HV terminals.
Features that can be
provided at extra cost :
Safely Measures :
Zero start interlocking is
provided to ensure that the
H.V. Circuit cannot be
energized unless the
regulating transformer is at
Zero position or brought
back to zero position after
each test, A transparent
cutout with suitable
interlocking device is
provided for covering the
H.T. side. The set will not
get energised unless the H.T.
end is covered.
Memory Switch :
Memory device along with
push button switch enables
the test set meter to show
the breakdown voltage by
pressing the memory switch
even after the high voltage
circuit is tripped OFF>